Ensure that the old version of Gateway is running.
Navigate to the extracted folder of the new version of the Gateway.
Execute the script
update.sh
by providing the old Gateway directory and new Gateway directory.
LinuxCode Block ./update.sh -orig <path_to_old_version_directory> -dest <path_to_new_version_directory>
Windows
Code Block .\update.bat -orig <path_to_old_version_directory> -dest <path_to_new_version_directory>
Remote Update
Note that this requires an SSH Server to be installed on the Gateway’s Host system.
Get proxy information of the gateway’s connection.
CurlCode Block curl --location 'https://<UPLINK SERVICE URL>/api/device/<CAMERA_ID FROM GATEWAY ACCESS TOKEN>' --header 'Authorization: Bearer <UPLINK SERVICE PASSWORD>'
Response
Code Block {"camid": "3045", "proxy_id": "b4d185e7efdfa0f4ce01", "forwards": [{"name": "camera-gateway-http", "protocol": "http", "host": "127.0.0.1", "port": 80, "proxy_port_number": 33984, "proxy_host": "b4d185e7efdfa0f4ce01.proxy.cloud-vms.com", "proxy_url": "http://b4d185e7efdfa0f4ce01.proxy.cloud-vms.com:33984", "proxy_port": 33984}, {"name": "camera-gateway-ssh", "protocol": "tcp", "host": "172.31.2.21", "port": 22, "proxy_port_number": 33985, "proxy_host": "b4d185e7efdfa0f4ce01.proxy.cloud-vms.com", "proxy_port": 33985}]}
Connect to device via the SSH info.
Code Block ssh -i <PATH TO .PEM> <USERNAME>@a4f9efe5b9e887b79001.proxy.cloud-vms.com -p 34917
Connection method may vary depending on how your SSH Client is configured on the host machine.
Upload or download the Gateway version you want to update to onto the Gateway device.
Navigate to the directory containing the new version of the Gateway.
Execute the update script as a background process. Note that the connection will be broken as the Gateway restarts.
LinuxCode Block nohup sudo ./update.sh -orig <path_to_old_version_directory> -dest <path_to_new_version_directory> &
Windows
Code Block Start-Process .\update.bat -orig <path_to_old_version_directory> -dest <path_to_new_version_directory> -NoNewWindow
If done successfully the Gateway should be accessible from it’s original IP.
...